Loading...

Sensor

Teledyne Oxygen Sensor - Detail

CLASS PART No. APPLICATION
A-1
oxygen sensor
C6689-A1 Ultra-fast response (90% in less than 4 seconds) in the percent oxygen region.
A-2C
oxygen sensor
C6689-A2C Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present.
A-2CXL
oxygen sensor
B74033-A2CXL Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm.
A-5
oxygen sensor
C6689-A5 Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2.90% response is time is 45 seconds.
B-1
oxygen sensor
C6689-B1 General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds).
B-2C
oxygen sensor
C6689-B2C General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm.
INSTA TRACE
oxygen sensor
B71875 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm.
B-2CXL
oxygen sensor
C6689-B2CXL Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm.
B-3
oxygen sensor
C6689-B3 Percent O2 analysis, best compromise between long life and fast response.
B-4C
oxygen sensor
C14613-B4C Trace O2 cell specifically designed for the Model 317EXI.
B-5
oxygen sensor
C45091-B5 Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3.
B-5F
oxygen sensor
C45091-B5F Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required.
B-7
oxygen sensor
C45091-B7 Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell.
B-7F
oxygen sensor
C45091-B7F Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required.
C-1
oxygen sensor
C6689-C1 Rarely used. Schematic for reference only.
C-2
oxygen sensor
C6689-C2 Rarely used. Schematic for reference only.
C-3
oxygen sensor
C6689-C3 Percent O2 measurements where maximum cell life is desired (high O2 applications).
C-5
oxygen sensor
C45091-C5 Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell.
C-5F
oxygen sensor
C45091-C5F Special application cell (non-standard) where long life, in the presence of CO2, is required.
C-6
oxygen sensor
C54090-C6 Motion insensitive percent O2 measurements for use in hand held portable monitors.
E-1
oxygen sensor
C14991-E1 Special cell with performance characteristic of the C-3 with 5x the life.
E-2
oxygen sensor
C57283-E2 Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids).
F-1R C40371-F1R 0-1000 ppm CO in Air
F-3 C55194-F3 Rarely used. Schematic for reference only.
INSTA TRACE - CO2 B73016 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Used for trace O2 measurements in CO2 containing backgrounds (0-100% CO2) in the 3000T analyzer series.
INSTA TRACE - XL
oxygen sensor
B73592 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Specially qualified sensor to operate in XL model analyzers with a low range limit of 0-1 ppm.
K-1
oxygen sensor
C43832-K1 Smallest Micro-fuel Cell, for use in applications where small size or multiple sensing requirements exist.
L-2C
oxygen sensor
C6689-L2C Used for general purpose trace oxygen analysis in the 3000T analyzer series.
L-2CI
oxygen sensor
C6689-L2CI Used in the Model 3000T series for trace O2 measurements; use only in CO2 and H2 background mixtures (e.g. inert gas generators).
S-2C
oxygen sensor
C6689-S2C Trace oxygen cell for use in TurbO2 analyzer. Provides rapid recovery from air calibration (approximately 20 minutes).
Z-2C
oxygen sensor
C6689-Z2C Has the same features as the S-2, except configured for use in the Model 3190.